Diagnose water carryover between rinser and filler

A repeatable sample record to compare residual water after rinsing and at filler infeed across formats and speeds.

Italiano

This worksheet compares the water remaining in a container at two documented pick-off points: after the last rinse and before filling. Follow the equipment and quality team's approved method for collecting empty containers. A fixed sample method keeps differences in handling from showing up as a machine effect.

Record residual water per container

Matched sample record
FieldSequence ASequence B
Bottle and methodRecord format, batch and the dry reference mass for each test container or the approved reference set.Use the same reference method. Keep differing formats separate.
Pick-off pointTake matched samples at the agreed exit of the rinser.Take matched samples just before the filler.
TimingRecord running speed and elapsed time from collection to weighing.Weigh at the same elapsed time and note any extra handling.
ResultSubtract the dry reference mass from the collected bottle mass.Compare the distribution and outliers against the agreed criterion.

Read the pattern

An illustrative bottle that weighs 24.8 g dry and 25.2 g at measurement has a 0.4 g mass difference. This is a calculation example. Assess your own limits for the product and container. If the difference increases with speed, compare the drainage time under the two operating points. Frequent outliers at a single speed warrant checking station identity and bottle orientation. Keep the very first containers after a restart separate from steady production samples.

If the result leads to a machine comparison, the air-and-water rinser treatment brief lists the treatment and utilities evidence to bring to a site visit.

Send your format, running speed and matched sample results for a machinery discussion.