This worksheet compares the water remaining in a container at two documented pick-off points: after the last rinse and before filling. Follow the equipment and quality team's approved method for collecting empty containers. A fixed sample method keeps differences in handling from showing up as a machine effect.
Record residual water per container
| Field | Sequence A | Sequence B |
|---|---|---|
| Bottle and method | Record format, batch and the dry reference mass for each test container or the approved reference set. | Use the same reference method. Keep differing formats separate. |
| Pick-off point | Take matched samples at the agreed exit of the rinser. | Take matched samples just before the filler. |
| Timing | Record running speed and elapsed time from collection to weighing. | Weigh at the same elapsed time and note any extra handling. |
| Result | Subtract the dry reference mass from the collected bottle mass. | Compare the distribution and outliers against the agreed criterion. |
Read the pattern
An illustrative bottle that weighs 24.8 g dry and 25.2 g at measurement has a 0.4 g mass difference. This is a calculation example. Assess your own limits for the product and container. If the difference increases with speed, compare the drainage time under the two operating points. Frequent outliers at a single speed warrant checking station identity and bottle orientation. Keep the very first containers after a restart separate from steady production samples.
If the result leads to a machine comparison, the air-and-water rinser treatment brief lists the treatment and utilities evidence to bring to a site visit.
Send your format, running speed and matched sample results for a machinery discussion.